AGSI Storage Inventory
ALSI LNG Inventory
UMM Inside Information
UMM detail - REMIT Urgent Market Messages
- Message ID:
- 24080121X000000001075A106_003
- Publication Date/Time:
- 2024-08-01 08:10:10 UTC
- Market Participant:
- Nederlandse Aardolie Maatschappij B.V.
- Market Participant Code:
- A0005524K.NL
- Balancing Zone:
- Dutch Balancing zone
- Balancing Zone Code:
- 21YNL----TTF---1
- Affected Asset or Unit:
-
NORG-NAM
- Affected Asset or Unit Code:
-
21W000000000015A
- Event Start:
- 2024-08-01 07:00:00 UTC
- Event Stop:
- 2024-08-01 08:00:00 UTC
- Event Status:
- Inactive
- Type of Event:
- Injection unavailability
- Direction:
- Unavailable Capacity:
- 4.000000000 GWh/d
- Available Capacity:
- 343.000000000 GWh/d
- Technical Capacity:
- 347.000000000 GWh/d
- Type of Unavailability:
- Unplanned
- Reason for the Unavailability:
- compressor trip becaus of electrical problems by Tennet (spanningsdip)
UPDATE: electrical problems are resovled. therefore compressor can be back in running from 10 HR LET. - Remarks:
- electrical specialist has to review compressor electrical mains for damage and reset, before start.
UPDATE: electrical problems are resovled. therefore compressor can be back in running from 10 HR LET.
- Message ID:
- 24080121X000000001075A106_002
- Publication Date/Time:
- 2024-08-01 07:26:32 UTC
- Market Participant:
- Nederlandse Aardolie Maatschappij B.V.
- Market Participant Code:
- A0005524K.NL
- Balancing Zone:
- Dutch Balancing zone
- Balancing Zone Code:
- 21YNL----TTF---1
- Affected Asset or Unit:
-
NORG-NAM
- Affected Asset or Unit Code:
-
21W000000000015A
- Event Start:
- 2024-08-01 07:00:00 UTC
- Event Stop:
- 2024-08-01 08:00:00 UTC
- Event Status:
- Active
- Type of Event:
- Injection unavailability
- Direction:
- Unavailable Capacity:
- 4.000000000 GWh/d
- Available Capacity:
- 343.000000000 GWh/d
- Technical Capacity:
- 347.000000000 GWh/d
- Type of Unavailability:
- Unplanned
- Reason for the Unavailability:
- compressor trip becaus of electrical problems by Tennet (spanningsdip)
UPDATE: electrical problems are resovled. therefore compressor can be back in running from 10 HR LET. - Remarks:
- electrical specialist has to review compressor electrical mains for damage and reset, before start.
UPDATE: electrical problems are resovled. therefore compressor can be back in running from 10 HR LET.
- Message ID:
- 24080121X000000001075A106_001
- Publication Date/Time:
- 2024-08-01 06:31:18 UTC
- Market Participant:
- Nederlandse Aardolie Maatschappij B.V.
- Market Participant Code:
- A0005524K.NL
- Balancing Zone:
- Dutch Balancing zone
- Balancing Zone Code:
- 21YNL----TTF---1
- Affected Asset or Unit:
-
NORG-NAM
- Affected Asset or Unit Code:
-
21W000000000015A
- Event Start:
- 2024-08-01 07:00:00 UTC
- Event Stop:
- 2024-08-01 10:00:00 UTC
- Event Status:
- Active
- Type of Event:
- Injection unavailability
- Direction:
- Unavailable Capacity:
- 11.000000000 GWh/d
- Available Capacity:
- 336.000000000 GWh/d
- Technical Capacity:
- 347.000000000 GWh/d
- Type of Unavailability:
- Unplanned
- Reason for the Unavailability:
- compressor trip becaus of electrical problems by Tennet (spanningsdip)
- Remarks:
- electrical specialist has to review compressor electrical mains for damage and reset, before start.